Why do some multimeters have discrete ranges for measurable values and some just measure based on signal...












3












$begingroup$


I have a multimeter in my toolbox that has ranges of values it measures in dc voltage, a lot like the one below which can read DC but reads it by orders of magnitude. In order to get a proper reading I have to select the correct range, otherwise my meter reads 0.00L.



enter image description here



I was browsing some tools on amazon and found this meter which, excepting amperage, does not need to have a range selected discretely. I was curious, it's obviously possible to do as this meter exists -- so why do your regular off-the-shelf wal-meters require you to select the value range?



enter image description here










share|improve this question









$endgroup$








  • 2




    $begingroup$
    Tools and devices differ in their complexity and cost. Like anything else. You have self-driving cars today - why not all of the cars then?
    $endgroup$
    – Eugene Sh.
    Jan 21 at 16:10








  • 2




    $begingroup$
    Note: The top manual range meter is $10, and the bottom auto ranging clamp meter is $27. Obviously these are both on the "budget" range for meters, but it shows just how inexpensive the manual meter is. Every cent counts in that part of the market.
    $endgroup$
    – JPhi1618
    Jan 21 at 19:53
















3












$begingroup$


I have a multimeter in my toolbox that has ranges of values it measures in dc voltage, a lot like the one below which can read DC but reads it by orders of magnitude. In order to get a proper reading I have to select the correct range, otherwise my meter reads 0.00L.



enter image description here



I was browsing some tools on amazon and found this meter which, excepting amperage, does not need to have a range selected discretely. I was curious, it's obviously possible to do as this meter exists -- so why do your regular off-the-shelf wal-meters require you to select the value range?



enter image description here










share|improve this question









$endgroup$








  • 2




    $begingroup$
    Tools and devices differ in their complexity and cost. Like anything else. You have self-driving cars today - why not all of the cars then?
    $endgroup$
    – Eugene Sh.
    Jan 21 at 16:10








  • 2




    $begingroup$
    Note: The top manual range meter is $10, and the bottom auto ranging clamp meter is $27. Obviously these are both on the "budget" range for meters, but it shows just how inexpensive the manual meter is. Every cent counts in that part of the market.
    $endgroup$
    – JPhi1618
    Jan 21 at 19:53














3












3








3


1



$begingroup$


I have a multimeter in my toolbox that has ranges of values it measures in dc voltage, a lot like the one below which can read DC but reads it by orders of magnitude. In order to get a proper reading I have to select the correct range, otherwise my meter reads 0.00L.



enter image description here



I was browsing some tools on amazon and found this meter which, excepting amperage, does not need to have a range selected discretely. I was curious, it's obviously possible to do as this meter exists -- so why do your regular off-the-shelf wal-meters require you to select the value range?



enter image description here










share|improve this question









$endgroup$




I have a multimeter in my toolbox that has ranges of values it measures in dc voltage, a lot like the one below which can read DC but reads it by orders of magnitude. In order to get a proper reading I have to select the correct range, otherwise my meter reads 0.00L.



enter image description here



I was browsing some tools on amazon and found this meter which, excepting amperage, does not need to have a range selected discretely. I was curious, it's obviously possible to do as this meter exists -- so why do your regular off-the-shelf wal-meters require you to select the value range?



enter image description here







multimeter






share|improve this question













share|improve this question











share|improve this question




share|improve this question










asked Jan 21 at 16:06









SidneySidney

1433




1433








  • 2




    $begingroup$
    Tools and devices differ in their complexity and cost. Like anything else. You have self-driving cars today - why not all of the cars then?
    $endgroup$
    – Eugene Sh.
    Jan 21 at 16:10








  • 2




    $begingroup$
    Note: The top manual range meter is $10, and the bottom auto ranging clamp meter is $27. Obviously these are both on the "budget" range for meters, but it shows just how inexpensive the manual meter is. Every cent counts in that part of the market.
    $endgroup$
    – JPhi1618
    Jan 21 at 19:53














  • 2




    $begingroup$
    Tools and devices differ in their complexity and cost. Like anything else. You have self-driving cars today - why not all of the cars then?
    $endgroup$
    – Eugene Sh.
    Jan 21 at 16:10








  • 2




    $begingroup$
    Note: The top manual range meter is $10, and the bottom auto ranging clamp meter is $27. Obviously these are both on the "budget" range for meters, but it shows just how inexpensive the manual meter is. Every cent counts in that part of the market.
    $endgroup$
    – JPhi1618
    Jan 21 at 19:53








2




2




$begingroup$
Tools and devices differ in their complexity and cost. Like anything else. You have self-driving cars today - why not all of the cars then?
$endgroup$
– Eugene Sh.
Jan 21 at 16:10






$begingroup$
Tools and devices differ in their complexity and cost. Like anything else. You have self-driving cars today - why not all of the cars then?
$endgroup$
– Eugene Sh.
Jan 21 at 16:10






2




2




$begingroup$
Note: The top manual range meter is $10, and the bottom auto ranging clamp meter is $27. Obviously these are both on the "budget" range for meters, but it shows just how inexpensive the manual meter is. Every cent counts in that part of the market.
$endgroup$
– JPhi1618
Jan 21 at 19:53




$begingroup$
Note: The top manual range meter is $10, and the bottom auto ranging clamp meter is $27. Obviously these are both on the "budget" range for meters, but it shows just how inexpensive the manual meter is. Every cent counts in that part of the market.
$endgroup$
– JPhi1618
Jan 21 at 19:53










2 Answers
2






active

oldest

votes


















8












$begingroup$

The ones that don't require you to set a range have a feature called "auto-ranging". It's a feature that makes the meter easier to use — especially in the field — but sometimes slower to settle on a reading. It adds a bit of complexity to the meter logic (and the user interface), which is why the cheapest meters don't have it.






share|improve this answer









$endgroup$









  • 3




    $begingroup$
    +1 As an aside, just because the meter doesn't appear to have range settings you (@Sidney) can't assume that it is autoranging. It may be that the meter really has just one range.
    $endgroup$
    – Elliot Alderson
    Jan 21 at 16:29






  • 4




    $begingroup$
    "easier to use"? Sometimes autoranging gets stuck in a cycle doing alternating readings on adjacent ranges. Especially ohmmeters. PITA. Having discretely selectable ranges turns off autoranging, allowing a stable display. This option is worthwhile having. Pure autoranging with no discrete scale ranges on the selector switch (2nd photo of OP's) is the low-cost method now, for a modern meter.
    $endgroup$
    – glen_geek
    Jan 21 at 16:53






  • 1




    $begingroup$
    @glen_geek Most meters I've used allow you to turn off the auto-ranging. It's a little inconvenient because you then need to use buttons to step up and down ranges, but autoranging getting stuck is uncommon enough that it's never been that big of a problem in my experience.
    $endgroup$
    – Hearth
    Jan 21 at 17:33










  • $begingroup$
    @Hearth Good point...OP's second photo shows a yellow HOLD push button. It likely means "hold-the-current reading" rather than "hold-the-current-range". I'd prefer the latter. Autoranging can be annoyingly slow sometimes. The blue SELECT apparently chooses between continuity-check and diode-test.(it isn't a range select).
    $endgroup$
    – glen_geek
    Jan 21 at 17:58






  • 1




    $begingroup$
    I have an auto-ranging meter with a button that cycles through the ranges. It is definitely useful to turn off auto-ranging when e.g. you're measuring a (slow) 5V square wave as the meter won't hunt for the range every time the voltage changes.
    $endgroup$
    – immibis
    Jan 21 at 22:41



















2












$begingroup$

Many meters work by converting an input into a small voltage or current and then measuring that. There are a number of approaches meters can use to control their input range, which may be used individually or combined:




  1. Use a constant ratio of input signal to measured signal, and vary the relationship between the measured signal and the display. For example, a meter could scale an input scale by 1000:1, and then display the input scaled so that full-scale voltage is 400mV, 40mV, or 4mV. Such an approach used in isolation will generally limit a meter's useful dynamic range, since 0.1mV of noise would show up as 0.1V of noise in the measured value. Not a problem if the signal being measured is 300V, but very bad if the signal of interest is only 0.3V.


  2. Have several inputs to the measurement circuitry, which receive differently-divided inputs that are always fed to all of them. Have the measurement circuitry select whichever input is using a divide ratio appropriate to the signal being measured. This approach could be combined with the above approach by having inputs with 1000:1 and 10:1 dividers and then displaying the result scaled to show a full-scale voltage of 400mV or 40mV. Inputs over 4 volts would be read as above using the 1000:1 divider, but smaller inputs could use the input from the 10:1 divider, thus reducing 100-fold the effect of noise in the measurement circuitry.


  3. Change the ratio of input value to the voltage that appears at the measurement input.



Note that if a device is only measuring input voltage, approaches #1 and #2 are adequate if used together, since the meter will have little effect on the device or circuit being measured. When measuring resistance or current, however, the meter will need to affect the device under test, and there are trade-offs between accuracy and the amount of effect on the device being tested. One could theoretically measure any resistance by putting one milliamp through it and measuring the voltage, but getting an measurement that's accurate to 1% with a one ohm resistor would require measuring voltage accurate to 0.01mV--rather a tall order. On the flip side, measuring a one meg resistor using a 1mA current would require that one feed a watt into it, which would both be difficult for a meter to do, and might adversely affect the resistor being tested even if one could do it. Adjusting the measurement range for resistance and current is more easily accomplished by adjusting the effect of the measurement on the device under test so that it will produce a voltage in a certain range, but doing that may be more difficult than merely selecting an input. When sensing resistance, having a current source that can be switched under processor control between e.g. 0.1mA and 10mA may not be difficult, but changing the sense resistor when measuring current will generally be impractical.



A meter which uses a rotary switch to select input range can easily adjust how it measures things in whatever way is most convenient. A meter which selects ranges electronically may have more limited options.






share|improve this answer









$endgroup$













    Your Answer





    StackExchange.ifUsing("editor", function () {
    return StackExchange.using("mathjaxEditing", function () {
    StackExchange.MarkdownEditor.creationCallbacks.add(function (editor, postfix) {
    StackExchange.mathjaxEditing.prepareWmdForMathJax(editor, postfix, [["\$", "\$"]]);
    });
    });
    }, "mathjax-editing");

    StackExchange.ifUsing("editor", function () {
    return StackExchange.using("schematics", function () {
    StackExchange.schematics.init();
    });
    }, "cicuitlab");

    StackExchange.ready(function() {
    var channelOptions = {
    tags: "".split(" "),
    id: "135"
    };
    initTagRenderer("".split(" "), "".split(" "), channelOptions);

    StackExchange.using("externalEditor", function() {
    // Have to fire editor after snippets, if snippets enabled
    if (StackExchange.settings.snippets.snippetsEnabled) {
    StackExchange.using("snippets", function() {
    createEditor();
    });
    }
    else {
    createEditor();
    }
    });

    function createEditor() {
    StackExchange.prepareEditor({
    heartbeatType: 'answer',
    autoActivateHeartbeat: false,
    convertImagesToLinks: false,
    noModals: true,
    showLowRepImageUploadWarning: true,
    reputationToPostImages: null,
    bindNavPrevention: true,
    postfix: "",
    imageUploader: {
    brandingHtml: "Powered by u003ca class="icon-imgur-white" href="https://imgur.com/"u003eu003c/au003e",
    contentPolicyHtml: "User contributions licensed under u003ca href="https://creativecommons.org/licenses/by-sa/3.0/"u003ecc by-sa 3.0 with attribution requiredu003c/au003e u003ca href="https://stackoverflow.com/legal/content-policy"u003e(content policy)u003c/au003e",
    allowUrls: true
    },
    onDemand: true,
    discardSelector: ".discard-answer"
    ,immediatelyShowMarkdownHelp:true
    });


    }
    });














    draft saved

    draft discarded


















    StackExchange.ready(
    function () {
    StackExchange.openid.initPostLogin('.new-post-login', 'https%3a%2f%2felectronics.stackexchange.com%2fquestions%2f418087%2fwhy-do-some-multimeters-have-discrete-ranges-for-measurable-values-and-some-just%23new-answer', 'question_page');
    }
    );

    Post as a guest















    Required, but never shown

























    2 Answers
    2






    active

    oldest

    votes








    2 Answers
    2






    active

    oldest

    votes









    active

    oldest

    votes






    active

    oldest

    votes









    8












    $begingroup$

    The ones that don't require you to set a range have a feature called "auto-ranging". It's a feature that makes the meter easier to use — especially in the field — but sometimes slower to settle on a reading. It adds a bit of complexity to the meter logic (and the user interface), which is why the cheapest meters don't have it.






    share|improve this answer









    $endgroup$









    • 3




      $begingroup$
      +1 As an aside, just because the meter doesn't appear to have range settings you (@Sidney) can't assume that it is autoranging. It may be that the meter really has just one range.
      $endgroup$
      – Elliot Alderson
      Jan 21 at 16:29






    • 4




      $begingroup$
      "easier to use"? Sometimes autoranging gets stuck in a cycle doing alternating readings on adjacent ranges. Especially ohmmeters. PITA. Having discretely selectable ranges turns off autoranging, allowing a stable display. This option is worthwhile having. Pure autoranging with no discrete scale ranges on the selector switch (2nd photo of OP's) is the low-cost method now, for a modern meter.
      $endgroup$
      – glen_geek
      Jan 21 at 16:53






    • 1




      $begingroup$
      @glen_geek Most meters I've used allow you to turn off the auto-ranging. It's a little inconvenient because you then need to use buttons to step up and down ranges, but autoranging getting stuck is uncommon enough that it's never been that big of a problem in my experience.
      $endgroup$
      – Hearth
      Jan 21 at 17:33










    • $begingroup$
      @Hearth Good point...OP's second photo shows a yellow HOLD push button. It likely means "hold-the-current reading" rather than "hold-the-current-range". I'd prefer the latter. Autoranging can be annoyingly slow sometimes. The blue SELECT apparently chooses between continuity-check and diode-test.(it isn't a range select).
      $endgroup$
      – glen_geek
      Jan 21 at 17:58






    • 1




      $begingroup$
      I have an auto-ranging meter with a button that cycles through the ranges. It is definitely useful to turn off auto-ranging when e.g. you're measuring a (slow) 5V square wave as the meter won't hunt for the range every time the voltage changes.
      $endgroup$
      – immibis
      Jan 21 at 22:41
















    8












    $begingroup$

    The ones that don't require you to set a range have a feature called "auto-ranging". It's a feature that makes the meter easier to use — especially in the field — but sometimes slower to settle on a reading. It adds a bit of complexity to the meter logic (and the user interface), which is why the cheapest meters don't have it.






    share|improve this answer









    $endgroup$









    • 3




      $begingroup$
      +1 As an aside, just because the meter doesn't appear to have range settings you (@Sidney) can't assume that it is autoranging. It may be that the meter really has just one range.
      $endgroup$
      – Elliot Alderson
      Jan 21 at 16:29






    • 4




      $begingroup$
      "easier to use"? Sometimes autoranging gets stuck in a cycle doing alternating readings on adjacent ranges. Especially ohmmeters. PITA. Having discretely selectable ranges turns off autoranging, allowing a stable display. This option is worthwhile having. Pure autoranging with no discrete scale ranges on the selector switch (2nd photo of OP's) is the low-cost method now, for a modern meter.
      $endgroup$
      – glen_geek
      Jan 21 at 16:53






    • 1




      $begingroup$
      @glen_geek Most meters I've used allow you to turn off the auto-ranging. It's a little inconvenient because you then need to use buttons to step up and down ranges, but autoranging getting stuck is uncommon enough that it's never been that big of a problem in my experience.
      $endgroup$
      – Hearth
      Jan 21 at 17:33










    • $begingroup$
      @Hearth Good point...OP's second photo shows a yellow HOLD push button. It likely means "hold-the-current reading" rather than "hold-the-current-range". I'd prefer the latter. Autoranging can be annoyingly slow sometimes. The blue SELECT apparently chooses between continuity-check and diode-test.(it isn't a range select).
      $endgroup$
      – glen_geek
      Jan 21 at 17:58






    • 1




      $begingroup$
      I have an auto-ranging meter with a button that cycles through the ranges. It is definitely useful to turn off auto-ranging when e.g. you're measuring a (slow) 5V square wave as the meter won't hunt for the range every time the voltage changes.
      $endgroup$
      – immibis
      Jan 21 at 22:41














    8












    8








    8





    $begingroup$

    The ones that don't require you to set a range have a feature called "auto-ranging". It's a feature that makes the meter easier to use — especially in the field — but sometimes slower to settle on a reading. It adds a bit of complexity to the meter logic (and the user interface), which is why the cheapest meters don't have it.






    share|improve this answer









    $endgroup$



    The ones that don't require you to set a range have a feature called "auto-ranging". It's a feature that makes the meter easier to use — especially in the field — but sometimes slower to settle on a reading. It adds a bit of complexity to the meter logic (and the user interface), which is why the cheapest meters don't have it.







    share|improve this answer












    share|improve this answer



    share|improve this answer










    answered Jan 21 at 16:19









    Dave TweedDave Tweed

    119k9148257




    119k9148257








    • 3




      $begingroup$
      +1 As an aside, just because the meter doesn't appear to have range settings you (@Sidney) can't assume that it is autoranging. It may be that the meter really has just one range.
      $endgroup$
      – Elliot Alderson
      Jan 21 at 16:29






    • 4




      $begingroup$
      "easier to use"? Sometimes autoranging gets stuck in a cycle doing alternating readings on adjacent ranges. Especially ohmmeters. PITA. Having discretely selectable ranges turns off autoranging, allowing a stable display. This option is worthwhile having. Pure autoranging with no discrete scale ranges on the selector switch (2nd photo of OP's) is the low-cost method now, for a modern meter.
      $endgroup$
      – glen_geek
      Jan 21 at 16:53






    • 1




      $begingroup$
      @glen_geek Most meters I've used allow you to turn off the auto-ranging. It's a little inconvenient because you then need to use buttons to step up and down ranges, but autoranging getting stuck is uncommon enough that it's never been that big of a problem in my experience.
      $endgroup$
      – Hearth
      Jan 21 at 17:33










    • $begingroup$
      @Hearth Good point...OP's second photo shows a yellow HOLD push button. It likely means "hold-the-current reading" rather than "hold-the-current-range". I'd prefer the latter. Autoranging can be annoyingly slow sometimes. The blue SELECT apparently chooses between continuity-check and diode-test.(it isn't a range select).
      $endgroup$
      – glen_geek
      Jan 21 at 17:58






    • 1




      $begingroup$
      I have an auto-ranging meter with a button that cycles through the ranges. It is definitely useful to turn off auto-ranging when e.g. you're measuring a (slow) 5V square wave as the meter won't hunt for the range every time the voltage changes.
      $endgroup$
      – immibis
      Jan 21 at 22:41














    • 3




      $begingroup$
      +1 As an aside, just because the meter doesn't appear to have range settings you (@Sidney) can't assume that it is autoranging. It may be that the meter really has just one range.
      $endgroup$
      – Elliot Alderson
      Jan 21 at 16:29






    • 4




      $begingroup$
      "easier to use"? Sometimes autoranging gets stuck in a cycle doing alternating readings on adjacent ranges. Especially ohmmeters. PITA. Having discretely selectable ranges turns off autoranging, allowing a stable display. This option is worthwhile having. Pure autoranging with no discrete scale ranges on the selector switch (2nd photo of OP's) is the low-cost method now, for a modern meter.
      $endgroup$
      – glen_geek
      Jan 21 at 16:53






    • 1




      $begingroup$
      @glen_geek Most meters I've used allow you to turn off the auto-ranging. It's a little inconvenient because you then need to use buttons to step up and down ranges, but autoranging getting stuck is uncommon enough that it's never been that big of a problem in my experience.
      $endgroup$
      – Hearth
      Jan 21 at 17:33










    • $begingroup$
      @Hearth Good point...OP's second photo shows a yellow HOLD push button. It likely means "hold-the-current reading" rather than "hold-the-current-range". I'd prefer the latter. Autoranging can be annoyingly slow sometimes. The blue SELECT apparently chooses between continuity-check and diode-test.(it isn't a range select).
      $endgroup$
      – glen_geek
      Jan 21 at 17:58






    • 1




      $begingroup$
      I have an auto-ranging meter with a button that cycles through the ranges. It is definitely useful to turn off auto-ranging when e.g. you're measuring a (slow) 5V square wave as the meter won't hunt for the range every time the voltage changes.
      $endgroup$
      – immibis
      Jan 21 at 22:41








    3




    3




    $begingroup$
    +1 As an aside, just because the meter doesn't appear to have range settings you (@Sidney) can't assume that it is autoranging. It may be that the meter really has just one range.
    $endgroup$
    – Elliot Alderson
    Jan 21 at 16:29




    $begingroup$
    +1 As an aside, just because the meter doesn't appear to have range settings you (@Sidney) can't assume that it is autoranging. It may be that the meter really has just one range.
    $endgroup$
    – Elliot Alderson
    Jan 21 at 16:29




    4




    4




    $begingroup$
    "easier to use"? Sometimes autoranging gets stuck in a cycle doing alternating readings on adjacent ranges. Especially ohmmeters. PITA. Having discretely selectable ranges turns off autoranging, allowing a stable display. This option is worthwhile having. Pure autoranging with no discrete scale ranges on the selector switch (2nd photo of OP's) is the low-cost method now, for a modern meter.
    $endgroup$
    – glen_geek
    Jan 21 at 16:53




    $begingroup$
    "easier to use"? Sometimes autoranging gets stuck in a cycle doing alternating readings on adjacent ranges. Especially ohmmeters. PITA. Having discretely selectable ranges turns off autoranging, allowing a stable display. This option is worthwhile having. Pure autoranging with no discrete scale ranges on the selector switch (2nd photo of OP's) is the low-cost method now, for a modern meter.
    $endgroup$
    – glen_geek
    Jan 21 at 16:53




    1




    1




    $begingroup$
    @glen_geek Most meters I've used allow you to turn off the auto-ranging. It's a little inconvenient because you then need to use buttons to step up and down ranges, but autoranging getting stuck is uncommon enough that it's never been that big of a problem in my experience.
    $endgroup$
    – Hearth
    Jan 21 at 17:33




    $begingroup$
    @glen_geek Most meters I've used allow you to turn off the auto-ranging. It's a little inconvenient because you then need to use buttons to step up and down ranges, but autoranging getting stuck is uncommon enough that it's never been that big of a problem in my experience.
    $endgroup$
    – Hearth
    Jan 21 at 17:33












    $begingroup$
    @Hearth Good point...OP's second photo shows a yellow HOLD push button. It likely means "hold-the-current reading" rather than "hold-the-current-range". I'd prefer the latter. Autoranging can be annoyingly slow sometimes. The blue SELECT apparently chooses between continuity-check and diode-test.(it isn't a range select).
    $endgroup$
    – glen_geek
    Jan 21 at 17:58




    $begingroup$
    @Hearth Good point...OP's second photo shows a yellow HOLD push button. It likely means "hold-the-current reading" rather than "hold-the-current-range". I'd prefer the latter. Autoranging can be annoyingly slow sometimes. The blue SELECT apparently chooses between continuity-check and diode-test.(it isn't a range select).
    $endgroup$
    – glen_geek
    Jan 21 at 17:58




    1




    1




    $begingroup$
    I have an auto-ranging meter with a button that cycles through the ranges. It is definitely useful to turn off auto-ranging when e.g. you're measuring a (slow) 5V square wave as the meter won't hunt for the range every time the voltage changes.
    $endgroup$
    – immibis
    Jan 21 at 22:41




    $begingroup$
    I have an auto-ranging meter with a button that cycles through the ranges. It is definitely useful to turn off auto-ranging when e.g. you're measuring a (slow) 5V square wave as the meter won't hunt for the range every time the voltage changes.
    $endgroup$
    – immibis
    Jan 21 at 22:41













    2












    $begingroup$

    Many meters work by converting an input into a small voltage or current and then measuring that. There are a number of approaches meters can use to control their input range, which may be used individually or combined:




    1. Use a constant ratio of input signal to measured signal, and vary the relationship between the measured signal and the display. For example, a meter could scale an input scale by 1000:1, and then display the input scaled so that full-scale voltage is 400mV, 40mV, or 4mV. Such an approach used in isolation will generally limit a meter's useful dynamic range, since 0.1mV of noise would show up as 0.1V of noise in the measured value. Not a problem if the signal being measured is 300V, but very bad if the signal of interest is only 0.3V.


    2. Have several inputs to the measurement circuitry, which receive differently-divided inputs that are always fed to all of them. Have the measurement circuitry select whichever input is using a divide ratio appropriate to the signal being measured. This approach could be combined with the above approach by having inputs with 1000:1 and 10:1 dividers and then displaying the result scaled to show a full-scale voltage of 400mV or 40mV. Inputs over 4 volts would be read as above using the 1000:1 divider, but smaller inputs could use the input from the 10:1 divider, thus reducing 100-fold the effect of noise in the measurement circuitry.


    3. Change the ratio of input value to the voltage that appears at the measurement input.



    Note that if a device is only measuring input voltage, approaches #1 and #2 are adequate if used together, since the meter will have little effect on the device or circuit being measured. When measuring resistance or current, however, the meter will need to affect the device under test, and there are trade-offs between accuracy and the amount of effect on the device being tested. One could theoretically measure any resistance by putting one milliamp through it and measuring the voltage, but getting an measurement that's accurate to 1% with a one ohm resistor would require measuring voltage accurate to 0.01mV--rather a tall order. On the flip side, measuring a one meg resistor using a 1mA current would require that one feed a watt into it, which would both be difficult for a meter to do, and might adversely affect the resistor being tested even if one could do it. Adjusting the measurement range for resistance and current is more easily accomplished by adjusting the effect of the measurement on the device under test so that it will produce a voltage in a certain range, but doing that may be more difficult than merely selecting an input. When sensing resistance, having a current source that can be switched under processor control between e.g. 0.1mA and 10mA may not be difficult, but changing the sense resistor when measuring current will generally be impractical.



    A meter which uses a rotary switch to select input range can easily adjust how it measures things in whatever way is most convenient. A meter which selects ranges electronically may have more limited options.






    share|improve this answer









    $endgroup$


















      2












      $begingroup$

      Many meters work by converting an input into a small voltage or current and then measuring that. There are a number of approaches meters can use to control their input range, which may be used individually or combined:




      1. Use a constant ratio of input signal to measured signal, and vary the relationship between the measured signal and the display. For example, a meter could scale an input scale by 1000:1, and then display the input scaled so that full-scale voltage is 400mV, 40mV, or 4mV. Such an approach used in isolation will generally limit a meter's useful dynamic range, since 0.1mV of noise would show up as 0.1V of noise in the measured value. Not a problem if the signal being measured is 300V, but very bad if the signal of interest is only 0.3V.


      2. Have several inputs to the measurement circuitry, which receive differently-divided inputs that are always fed to all of them. Have the measurement circuitry select whichever input is using a divide ratio appropriate to the signal being measured. This approach could be combined with the above approach by having inputs with 1000:1 and 10:1 dividers and then displaying the result scaled to show a full-scale voltage of 400mV or 40mV. Inputs over 4 volts would be read as above using the 1000:1 divider, but smaller inputs could use the input from the 10:1 divider, thus reducing 100-fold the effect of noise in the measurement circuitry.


      3. Change the ratio of input value to the voltage that appears at the measurement input.



      Note that if a device is only measuring input voltage, approaches #1 and #2 are adequate if used together, since the meter will have little effect on the device or circuit being measured. When measuring resistance or current, however, the meter will need to affect the device under test, and there are trade-offs between accuracy and the amount of effect on the device being tested. One could theoretically measure any resistance by putting one milliamp through it and measuring the voltage, but getting an measurement that's accurate to 1% with a one ohm resistor would require measuring voltage accurate to 0.01mV--rather a tall order. On the flip side, measuring a one meg resistor using a 1mA current would require that one feed a watt into it, which would both be difficult for a meter to do, and might adversely affect the resistor being tested even if one could do it. Adjusting the measurement range for resistance and current is more easily accomplished by adjusting the effect of the measurement on the device under test so that it will produce a voltage in a certain range, but doing that may be more difficult than merely selecting an input. When sensing resistance, having a current source that can be switched under processor control between e.g. 0.1mA and 10mA may not be difficult, but changing the sense resistor when measuring current will generally be impractical.



      A meter which uses a rotary switch to select input range can easily adjust how it measures things in whatever way is most convenient. A meter which selects ranges electronically may have more limited options.






      share|improve this answer









      $endgroup$
















        2












        2








        2





        $begingroup$

        Many meters work by converting an input into a small voltage or current and then measuring that. There are a number of approaches meters can use to control their input range, which may be used individually or combined:




        1. Use a constant ratio of input signal to measured signal, and vary the relationship between the measured signal and the display. For example, a meter could scale an input scale by 1000:1, and then display the input scaled so that full-scale voltage is 400mV, 40mV, or 4mV. Such an approach used in isolation will generally limit a meter's useful dynamic range, since 0.1mV of noise would show up as 0.1V of noise in the measured value. Not a problem if the signal being measured is 300V, but very bad if the signal of interest is only 0.3V.


        2. Have several inputs to the measurement circuitry, which receive differently-divided inputs that are always fed to all of them. Have the measurement circuitry select whichever input is using a divide ratio appropriate to the signal being measured. This approach could be combined with the above approach by having inputs with 1000:1 and 10:1 dividers and then displaying the result scaled to show a full-scale voltage of 400mV or 40mV. Inputs over 4 volts would be read as above using the 1000:1 divider, but smaller inputs could use the input from the 10:1 divider, thus reducing 100-fold the effect of noise in the measurement circuitry.


        3. Change the ratio of input value to the voltage that appears at the measurement input.



        Note that if a device is only measuring input voltage, approaches #1 and #2 are adequate if used together, since the meter will have little effect on the device or circuit being measured. When measuring resistance or current, however, the meter will need to affect the device under test, and there are trade-offs between accuracy and the amount of effect on the device being tested. One could theoretically measure any resistance by putting one milliamp through it and measuring the voltage, but getting an measurement that's accurate to 1% with a one ohm resistor would require measuring voltage accurate to 0.01mV--rather a tall order. On the flip side, measuring a one meg resistor using a 1mA current would require that one feed a watt into it, which would both be difficult for a meter to do, and might adversely affect the resistor being tested even if one could do it. Adjusting the measurement range for resistance and current is more easily accomplished by adjusting the effect of the measurement on the device under test so that it will produce a voltage in a certain range, but doing that may be more difficult than merely selecting an input. When sensing resistance, having a current source that can be switched under processor control between e.g. 0.1mA and 10mA may not be difficult, but changing the sense resistor when measuring current will generally be impractical.



        A meter which uses a rotary switch to select input range can easily adjust how it measures things in whatever way is most convenient. A meter which selects ranges electronically may have more limited options.






        share|improve this answer









        $endgroup$



        Many meters work by converting an input into a small voltage or current and then measuring that. There are a number of approaches meters can use to control their input range, which may be used individually or combined:




        1. Use a constant ratio of input signal to measured signal, and vary the relationship between the measured signal and the display. For example, a meter could scale an input scale by 1000:1, and then display the input scaled so that full-scale voltage is 400mV, 40mV, or 4mV. Such an approach used in isolation will generally limit a meter's useful dynamic range, since 0.1mV of noise would show up as 0.1V of noise in the measured value. Not a problem if the signal being measured is 300V, but very bad if the signal of interest is only 0.3V.


        2. Have several inputs to the measurement circuitry, which receive differently-divided inputs that are always fed to all of them. Have the measurement circuitry select whichever input is using a divide ratio appropriate to the signal being measured. This approach could be combined with the above approach by having inputs with 1000:1 and 10:1 dividers and then displaying the result scaled to show a full-scale voltage of 400mV or 40mV. Inputs over 4 volts would be read as above using the 1000:1 divider, but smaller inputs could use the input from the 10:1 divider, thus reducing 100-fold the effect of noise in the measurement circuitry.


        3. Change the ratio of input value to the voltage that appears at the measurement input.



        Note that if a device is only measuring input voltage, approaches #1 and #2 are adequate if used together, since the meter will have little effect on the device or circuit being measured. When measuring resistance or current, however, the meter will need to affect the device under test, and there are trade-offs between accuracy and the amount of effect on the device being tested. One could theoretically measure any resistance by putting one milliamp through it and measuring the voltage, but getting an measurement that's accurate to 1% with a one ohm resistor would require measuring voltage accurate to 0.01mV--rather a tall order. On the flip side, measuring a one meg resistor using a 1mA current would require that one feed a watt into it, which would both be difficult for a meter to do, and might adversely affect the resistor being tested even if one could do it. Adjusting the measurement range for resistance and current is more easily accomplished by adjusting the effect of the measurement on the device under test so that it will produce a voltage in a certain range, but doing that may be more difficult than merely selecting an input. When sensing resistance, having a current source that can be switched under processor control between e.g. 0.1mA and 10mA may not be difficult, but changing the sense resistor when measuring current will generally be impractical.



        A meter which uses a rotary switch to select input range can easily adjust how it measures things in whatever way is most convenient. A meter which selects ranges electronically may have more limited options.







        share|improve this answer












        share|improve this answer



        share|improve this answer










        answered Jan 21 at 17:53









        supercatsupercat

        38.3k163111




        38.3k163111






























            draft saved

            draft discarded




















































            Thanks for contributing an answer to Electrical Engineering Stack Exchange!


            • Please be sure to answer the question. Provide details and share your research!

            But avoid



            • Asking for help, clarification, or responding to other answers.

            • Making statements based on opinion; back them up with references or personal experience.


            Use MathJax to format equations. MathJax reference.


            To learn more, see our tips on writing great answers.




            draft saved


            draft discarded














            StackExchange.ready(
            function () {
            StackExchange.openid.initPostLogin('.new-post-login', 'https%3a%2f%2felectronics.stackexchange.com%2fquestions%2f418087%2fwhy-do-some-multimeters-have-discrete-ranges-for-measurable-values-and-some-just%23new-answer', 'question_page');
            }
            );

            Post as a guest















            Required, but never shown





















































            Required, but never shown














            Required, but never shown












            Required, but never shown







            Required, but never shown

































            Required, but never shown














            Required, but never shown












            Required, but never shown







            Required, but never shown







            Popular posts from this blog

            Mario Kart Wii

            The Binding of Isaac: Rebirth/Afterbirth

            What does “Dominus providebit” mean?